Quick answer: build the robot's duty cycle for one working hour (minutes and power for driving, lifting and waiting), multiply by the shift length and divide by about 0.8. An AMR using about 246 Wh per hour needs about 2 kWh per 8-hour shift and about 2.5 kWh installed. Two shifts without charging need about 4.9 kWh, which at 25.6 V is beyond our largest pack, so the choice becomes 51.2 V, opportunity charging or a lighter lithium-ion pack.
"High capacity" in a mobile robot is always a trade: every extra kilowatt-hour adds weight the robot has to carry, accelerate and fit in its chassis. This guide sizes an AMR battery step by step, then shows where the limits are. For voltage and chemistry choices, read LiFePO4 batteries for AGVs and AMRs; for charging strategies, AGV battery charging.
Step 1: build the duty cycle
Average power hides the details that matter. Break a typical working hour into activities and estimate each one's power and time. The figures below are example inputs for an AMR on a 25.6 V system; replace them with your own measurements.
| Activity | Time per hour | Power | Energy per hour |
|---|---|---|---|
| Driving with a load | 20 min | 400 W | 133.3 Wh |
| Driving empty | 15 min | 250 W | 62.5 Wh |
| Lifting | 2 min | 800 W | 26.7 Wh |
| Waiting (computer, sensors) | 23 min | 60 W | 23.0 Wh |
| Total | 60 min | 245.5 Wh |
Waiting time is easy to forget: the computer, lidar, cameras and wireless link draw power even when the robot stands still. In this example it is almost a tenth of the energy.

Step 2: from one hour to a full shift
- One 8-hour shift: 246 Wh × 8 ≈ 1.96 kWh.
- Installed energy with about 80% usable, to allow for ageing, cold and a reserve: 1.96 ÷ 0.8 ≈ 2.46 kWh.
- At 25.6 V: the 25.6V 96Ah LiFePO4 pack (8S16P), about 2.5 kWh. At 51.2 V: the 51.2V 48Ah pack (16S8P), also about 2.5 kWh. Both use 128 IFR32700 cells, about 18.6 kg of cells.
The 0.8 factor is not optional. A pack loses capacity as it ages, delivers less in the cold, and should not be run completely flat every day. Sizing to 100% leaves no margin by the second year.
Step 3: check the peaks
Energy decides runtime; current decides whether the battery can deliver. In the example, lifting draws 800 W, about 31 A at 25.6 V. Acceleration with a full load, ramps and emergency stops can draw more for short moments. Measure them, and size the BMS and connectors for the peak with margin. Our IFR32700 packs are rated 18 A per parallel group at cell level, so the 16-group pack's cells are rated for 288 A; the BMS rating, not the cells, usually sets the limit.
Two shifts: bigger battery, higher voltage or charging?
Running the same robot for 16 hours without charging needs 246 Wh × 16 ÷ 0.8 ≈ 4.9 kWh. Three ways to get there:
- A bigger 51.2 V pack: the 51.2V 96Ah pack (16S16P) stores about 4.9 kWh, but its 256 cells weigh about 37 kg before the BMS and enclosure. At 25.6 V, our largest pack, the 25.6V 120Ah, stores about 3.1 kWh and is not enough.
- Opportunity charging: if the robot spends 8 minutes of each hour at a 1 kW dock, it puts back about 133 Wh per hour. The pack then only covers about 113 Wh per hour: 113 × 16 ÷ 0.8 ≈ 2.3 kWh, so the same 2.5 kWh pack covers both shifts. Check that the cells, BMS and contacts accept the charge current: 1 kW at 25.6 V is about 39 A, or about 2.4 A per cell in a 16P pack; confirm the cells' maximum charge current against their datasheet.
- Lithium-ion for weight: at cell level, IFR32700 LiFePO4 weighs about 7.6 kg per kWh and the Molicel P45B lithium-ion cell about 4.3 kg per kWh. For 4.9 kWh that is roughly 37 kg against 21 kg of cells, at the cost of LiFePO4's cycle life and thermal stability. See LiFePO4 vs lithium-ion.
For most fleets with regular idle moments, opportunity charging gives the lightest robot. A bigger battery suits robots that cannot stop to charge during the shift.
How big can a robot battery get?
| Pack | Energy | Cells | Cell weight (calculated) |
|---|---|---|---|
| 25.6V 96Ah (8S16P) | 2.5 kWh | 128 | about 18.6 kg |
| 25.6V 120Ah (8S20P) | 3.1 kWh | 160 | about 23.2 kg |
| 51.2V 72Ah (16S12P) | 3.7 kWh | 192 | about 27.8 kg |
| 51.2V 96Ah (16S16P) | 4.9 kWh | 256 | about 37.1 kg |
| 51.2V 120Ah (16S20P) | 6.1 kWh | 320 | about 46.4 kg |
Energy as stated on the product pages; cell weight is the cell count × 145 g, before the BMS, wiring and enclosure. Above this, space and payload usually set the limit before the battery does. Other capacities are built on request: see the AGV and robot battery range.
Practical tips
- Measure, then size. Log current over a few real shifts with a smart BMS; estimates of idle power are often low.
- Size for winter. Robots in unheated warehouses or cold stores get less energy from the same pack, and must not charge below about 0 °C unless the pack is designed for it.
- Leave a reserve for the end of the shift. Fleet software should send a robot to charge before the BMS limits power.
- Read state of charge from the BMS. LiFePO4 voltage is flat over most of the discharge; see robot battery communication: CAN, RS485 and SMBus.
Getting a high-capacity robot battery
Send us the duty cycle or logged current, the shift pattern, the charging options, the space and weight limits and the communication protocol. Our engineers will size the pack, the BMS and the charging path together. Request a quote, see our AMR and AGV batteries, or lay out a pack in the Battery Design Studio (this link opens the 25.6 V 8S16P IFR32700 pack from the example).
Frequently asked questions
How much battery capacity does an AMR need for an 8-hour shift?
Multiply the robot's average power over a working hour by the shift length, then divide by about 0.8 for ageing, temperature and reserve. An AMR averaging 246 W needs about 2 kWh per shift and about 2.5 kWh installed.
What is the largest battery you can fit in a mobile robot?
It is set by space, weight and payload more than by the battery. Our largest LiFePO4 robot packs store about 3.1 kWh at 25.6 V and about 6.1 kWh at 51.2 V; their cells alone weigh about 23 kg and 46 kg.
Is opportunity charging better than a bigger battery?
If the robot has regular idle moments near a charger, usually yes: the pack only has to cover the work between top-ups, so it can be much smaller and lighter. A bigger battery suits robots that cannot stop to charge.
Should a high-capacity robot battery be LiFePO4 or lithium-ion?
LiFePO4 for cycle life and thermal stability where weight is acceptable; lithium-ion where every kilogram counts. At cell level, IFR32700 LiFePO4 weighs about 7.6 kg per kWh and the Molicel P45B about 4.3 kg per kWh.
How do I measure my robot's duty cycle?
Log battery current and voltage over a few representative shifts, or estimate each activity's power and time per hour. A smart BMS with CAN or RS485 can record the data for you.