Insights AGV & Robot Battery

AGV Battery Charging: Shift Charging, Opportunity Charging or Battery Swapping

The way an AGV or mobile robot charges decides how big its battery has to be. Here is how shift charging, opportunity charging and battery swapping compare, with a worked example that halves the pack.

Autonomous mobile robot (AGV) at its charging dock in a warehouse, with its battery bay open showing an EEMENTOR ENERGY 48V 48Ah LiFePO4 battery pack in a black ABS case
Autonomous mobile robot (AGV) at its charging dock in a warehouse, with its battery bay open showing an EEMENTOR ENERGY 48V 48Ah LiFePO4 battery pack in a black ABS case

An AGV or mobile robot only earns its keep while it is moving. How and when its battery charges decides how much of the day it can work, and it also decides how big the battery has to be. A robot that tops up at a dock between jobs can carry a much smaller pack than one that must last a whole shift. This guide compares the three common strategies and shows what each one means for the pack. For voltage, chemistry and basic sizing, start with our AGV and robot battery guide.

Three ways to keep a robot running

Shift charging Opportunity charging Battery swapping
How it works The robot works a full shift, then charges while it is parked The robot tops up for a few minutes at a dock between jobs or during idle time A flat pack is exchanged for a charged one; the flat pack charges off the robot
Battery size Largest: the pack carries the whole shift Smallest: the pack only carries the gap between top-ups Small, but you need spare packs
Downtime The charging time between shifts A few minutes at a time, often while waiting for work The time to swap the pack
Infrastructure One charger per robot or a charging area Docks with automatic charging contacts, and fleet software that sends robots to charge Spare packs, a charging rack and a swap procedure
Suits Single-shift operation with a long break for charging Multi-shift or 24/7 operation with regular idle moments Multi-shift operation where robots cannot stop to charge
Timeline of three AGV charging strategies over an 8-hour shift: shift charging works the whole shift and charges afterwards; opportunity charging works 50 minutes and docks 10 minutes every hour; battery swapping works four hours, swaps the pack and works four more hours while the first pack charges off the robot.
One 8-hour shift under each strategy. The pack only has to cover the work between two charges.

Lithium packs accept partial charges, so a robot does not have to wait for a full charge before it goes back to work. That is what makes opportunity charging practical with lithium-ion and LiFePO4.

How the strategy changes the pack: a worked example

Take a robot on a 48 V system that averages 400 W over an 8-hour shift, including driving, lifting, idling and its onboard computer. These are example inputs; use your own measured load profile. As in how to size a battery pack, we size for about 80% usable capacity.

  • Shift charging. The robot uses 400 W × 8 h = 3.2 kWh per shift. With the margin, that is 4.0 kWh installed: the 48V 96Ah LiFePO4 pack (16S16P), 4.9 kWh.
  • Opportunity charging. If the robot docks for 10 minutes every hour at a 1.2 kW charger, it puts back 0.2 kWh per hour, 1.6 kWh per shift. The pack only has to cover the difference, 1.6 kWh, or 2.0 kWh with the margin: the 48V 48Ah LiFePO4 pack (16S8P), 2.5 kWh.
  • Battery swapping. With one swap at mid-shift, each pack covers four hours: 1.6 kWh, or 2.0 kWh with the margin. That is again the 2.5 kWh pack, but you need at least two per robot: one working, one charging.
Shift charging Opportunity charging Battery swapping
Pack on the robot 48V 96Ah, 16S16P 48V 48Ah, 16S8P 48V 48Ah, 16S8P
Energy 4.9 kWh 2.5 kWh 2.5 kWh per pack
Cells on the robot 256 128 128
Weight of the cells on the robot about 37.1 kg about 18.6 kg about 18.6 kg
Packs per robot 1 1 2 or more

Opportunity charging halves the pack on the robot and removes about 18.5 kg of cells, which leaves more payload and less mass to accelerate. Swapping gives the same light pack on the robot, but the total number of cells you buy is the same as for shift charging. The weights are for the cells alone (about 145 g per IFR32700 cell); the BMS, enclosure and connectors add to them.

Chart of the worked example, a 400 W robot on an 8-hour shift: shift charging needs the 48V 96Ah LiFePO4 pack, 4.9 kWh, with about 37.1 kg of cells; opportunity charging (10 minutes per hour at 1.2 kW) needs the 48V 48Ah pack, 2.5 kWh, about 18.6 kg of cells; battery swapping uses the 2.5 kWh pack on the robot, with two or more packs per robot.
Opportunity charging halves the pack on the robot. Swapping keeps the robot light but needs spare packs.

Charging current and charging time

Opportunity charging moves the hard work to the charger. In the example, 1.2 kW at 51.2 V is about 23 A into the pack, or about 2.9 A per cell in an 8P pack. Before you commit to a dock power, check that the cells, the BMS and the charging contacts are rated for that current, and confirm the cells' maximum charge current against their datasheet. A larger pack with more cells in parallel spreads the same charge current over more cells.

For a full charge, the time is roughly the capacity divided by the charge current, plus a constant-voltage finish at the end: a 48 Ah pack charged at 24 A needs about two hours plus the finish. Shift charging can use a slower charge over the break; swapping gives each spare pack the whole working period of the other pack to recharge.

Whatever the strategy, the charger must match the pack's chemistry and series count:

Pack in our AGV range Cells in series Nominal Charge to
24 V lithium-ion 7S 25.2 V 29.4 V
24 V LiFePO4 8S 25.6 V 29.2 V
36 V lithium-ion 10S 36.0 V 42.0 V
48 V lithium-ion 13S 46.8 V 54.6 V
48 V LiFePO4 16S 51.2 V 58.4 V
52 V lithium-ion 14S 50.4 V 58.8 V

Do not charge lithium packs below about 0 °C unless they are designed for it. In cold stores, plan the charging area in a warmer zone, or specify temperature sensors so the BMS can stop charging when it is too cold.

What the battery needs for each strategy

  • Shift charging: the largest capacity that fits the chassis and payload, and a charge port or charge display if operators plug in by hand.
  • Opportunity charging: a BMS and charging path rated for the dock current, and a smart BMS with UART, CAN or Bluetooth so the fleet software can read the state of charge and send robots to the dock in time. See what a BMS does.
  • Battery swapping: a rigid case that survives frequent handling, connectors rated for many mating cycles (for example Anderson or XT90), and identical packs, so any spare fits any robot. Our enclosure guide covers casings and connectors.

Which strategy to choose

  • One shift a day, with time to charge between shifts: shift charging is the simplest.
  • Two or three shifts, with regular idle moments between tasks: opportunity charging gives the lightest robot and the smallest pack.
  • Continuous operation where a robot cannot stop to charge: battery swapping, with spare packs charging in a rack.

Many fleets combine them, for example opportunity charging during the day and a full charge overnight.

Our AGV battery range

The AGV and robot battery range has 488 packs: lithium-ion packs at 24 V, 36 V, 48 V and 52 V and LiFePO4 packs at 24 V and 48 V, from 2P to 20P, built from thirteen 18650 and 21700 cells and IFR32700 LiFePO4 cells. The LiFePO4 packs run from 307 Wh to 6.1 kWh. Every pack is built to order with your choice of BMS rating, communication, connector and casing. Compare the chemistries in LiFePO4 vs lithium-ion.

An AGV battery is usually an industrial battery under the EU Battery Regulation; above 2 kWh, it needs a digital battery passport from 18 February 2027. Every EEMENTOR ENERGY™ pack in scope already ships with one: see the EU battery passport guide.

Request a quote

When you request a quote, tell us the robot's voltage, average and peak power, shift pattern and charging strategy, the dock or charger current if you plan opportunity charging, and the space and weight available. Our engineers will size the pack, the BMS and the charging path together. You can also lay out a pack in the Battery Design Studio.

Need a custom battery pack?

Design it in 3D in minutes, or send us your requirements for an engineering quote.

Design in 3D Request a quote
All articles