How to Size a Battery Pack: Watt-Hours, Runtime and Peak Current

A worked example that turns power and runtime into a complete battery specification: voltage, watt-hours, configuration and current.

Autonomous mobile robot with its lithium battery pack exposed in a warehouse
Autonomous mobile robot with its lithium battery pack exposed in a warehouse

The most common question we get is "what battery do I need?". You can answer most of it with a few simple calculations. Here is the method, with a worked example.

Step 1: power and voltage

Start with the average power your device draws (in watts) and the voltage its motor or electronics need. The current follows from I = P / V. A 500 W robot on a 48 V system draws about 500 / 46.8 ≈ 10.7 A on average (46.8 V is the nominal voltage of a 13S lithium-ion pack, the usual "48 V" battery).

Step 2: energy for the runtime

Energy (Wh) = power (W) × runtime (h). For 4 hours at 500 W you need 2,000 Wh delivered to the load.

Step 3: add margins

  • Usable depth of discharge: using 100% of the capacity every cycle shortens the battery's life. Designing for about 80% usable capacity is common.
  • Efficiency and temperature: converters, wiring and cold weather reduce the energy you get out.
  • Ageing: capacity drops over the battery's life; many designs plan for the end-of-life capacity, often 80% of new.

With 80% usable capacity: 2,000 Wh / 0.8 = 2,500 Wh installed.

Step 4: amp-hours and configuration

Capacity (Ah) = energy (Wh) / nominal voltage (V) = 2,500 / 46.8 ≈ 53.4 Ah. With 5 Ah cells such as the Samsung 50S, 11 cells in parallel give 55 Ah. The result is a 13S11P pack: 143 cells, 46.8 V, 55 Ah, about 2,574 Wh.

Worked example of battery pack sizing: a 500 W load for 4 hours needs 2,000 Wh; with 80% usable capacity that is 2,500 Wh installed; at 46.8 V that is about 53.4 Ah; with 5 Ah Samsung 50S cells a 13S11P pack gives 143 cells, 55 Ah and about 2,574 Wh.
From load to configuration: the worked example in this guide, step by step.

Step 5: check the current

  • Continuous: 10.7 A spread over 11 parallel cells is about 1 A per cell, well within the 50S rating and good for lifetime.
  • Peak: if the motors draw 60 A for 5 seconds at start-up, the cells can easily supply it (11 × 25 A), but the BMS, fuse, wiring and connector must be rated for it too.

If your peaks are very high relative to your energy needs, a high-drain cell such as the Molicel P45B may let you use fewer parallel cells. See how to choose the right cell.

Step 6: check size and weight

143 cells of about 69 g weigh around 10 kg before the BMS, interconnects and enclosure. If that does not fit, revisit the runtime target, the chemistry or the cell. Our Battery Design Studio shows the weight and dimensions of any configuration instantly.

Information to send with a quote request

  • System voltage range, average power and runtime.
  • Continuous and peak current, with the peak duration.
  • Maximum permissible dimensions and weight.
  • Charger details, operating temperature, casing, connector and communication interface.

Our quote form asks for exactly these values, so you can request a quote directly from any product page. Read the full battery pack design guide and series vs parallel explained for the next steps.

Work with EEMENTOR ENERGY™

Have your numbers? Let us check them. Browse our custom battery packs and battery cells, design a pack in the Battery Design Studio, or request a quote and our engineering team will reply with pricing and lead time.

Need a custom battery pack?

Design it in 3D in minutes, or send us your requirements for an engineering quote.

Design in 3D Request a quote
All articles