Automated guided vehicles (AGVs), autonomous mobile robots and other electric carriers all depend on one component that decides how long they work between charges: the battery. The motors, sensors and controller set the voltage, the duty cycle sets the capacity, and the way the machine is used decides the chemistry. This guide walks through those choices, using the packs in our AGV and robot battery range as examples.
Choose by voltage
Most robot platforms use one of three voltage classes. Each has its own page with matching packs, a worked sizing example and the BMS communication options:
- 24V AGV batteries: 7S lithium-ion, 25.2 V nominal, for AMRs, service and delivery robots and light AGVs.
- 25.6V LiFePO4 AGV batteries: 8S LiFePO4 from 24 to 120 Ah, including the 25.6V 60Ah service robot battery.
- 48V AGV batteries: 13S lithium-ion or 16S LiFePO4 for larger AGVs, tuggers and lifting AMRs.
Start with the system voltage
Most AGV and robot drive systems are built around a standard voltage class, and the battery has to match the motor controller's input range. Our range covers the common classes:
| Voltage class | Li-ion (3.6 V cells) | LiFePO4 (3.2 V cells) |
|---|---|---|
| 24 V | 7S, 25.2 V nominal | 8S, 25.6 V nominal |
| 36 V | 10S, 36 V nominal | – |
| 48 V | 13S, 46.8 V nominal | 16S, 51.2 V nominal |
| 52 V | 14S, 50.4 V nominal | – |
The "S" number is how many cells are connected in series. Because Li-ion and LiFePO4 cells have different voltages, a 24 V class pack needs seven Li-ion cells in series but eight LiFePO4 cells. If the notation is new to you, read series vs parallel explained.
Nominal voltage is only part of the story. The voltage swings as the pack charges and discharges: the 7S Li-ion pack runs from about 17.5 V empty to 29.4 V full, and an 8S LiFePO4 pack charges to 29.2 V (3.65 V per cell). Check that the controller, DC-DC converters and any onboard electronics accept the whole range, not just the nominal figure. Lower voltage classes suit small robots and carts; larger AGVs, tuggers and lifting equipment usually move to 48 V so they can deliver the same power at lower current. Our comparison of 48 V and 52 V packs goes into the higher classes in more detail.
Li-ion or LiFePO4?
Both chemistries are used in robots. The practical difference shows up when you compare two 24 V packs with ten cells in parallel:
| 24V 45Ah, 7S10P Molicel P45B | 24V 60Ah, 8S10P IFR32700 | |
|---|---|---|
| Chemistry | Li-ion (21700) | LiFePO4 (32700) |
| Nominal voltage | 25.2 V | 25.6 V |
| Capacity and energy | 45 Ah, about 1.1 kWh | 60 Ah, about 1.5 kWh |
| Cells | 70 | 80 |
| Cell-rated continuous current | 450 A (45 A per cell) | 180 A (18 A per cell) |
| Weight of the cells alone | about 4.9 kg (70 × 70 g) | about 11.6 kg (80 × 145 g) |
| Runtime at a steady 500 W (estimate) | about 2 hours | about 2.8 hours |
The figures come from the cell datasheets: the Molicel P45B is a 3.6 V, 4,500 mAh, 45 A cell at about 70 g, while the IFR32700 is a 3.2 V, 6,000 mAh, 18 A cell at about 145 g. That works out to roughly 231 Wh/kg for the P45B and 132 Wh/kg for the IFR32700, at cell level.
- Choose LiFePO4 when the machine runs many charge cycles, works long shifts and has room for the extra weight. LiFePO4 is known for its long cycle life and thermal stability. In a heavy AGV or tugger, extra battery weight is often not a problem, and sometimes it even helps traction.
- Choose Li-ion when weight and space are tight, such as in compact or fast robots, or when the drive needs very high peak current. The P45B pack above weighs less than half as much in cells and its cells can deliver more than twice the current.
For a wider look at the two chemistries, see LiFePO4 vs lithium-ion.

Sizing the pack for a shift
Capacity is sized from energy, not from amp-hours alone. The basic steps:
- Measure or estimate the average power of the machine over a typical working cycle, including driving, lifting, idling and the onboard computer and sensors.
- Multiply by the hours between charges. A machine that averages 300 W over an 8-hour shift uses 2.4 kWh.
- Add margin for battery ageing, cold conditions and so that the pack does not have to be run completely flat every day.
- Check the peak current when the robot accelerates, climbs a ramp or lifts a load. The cells, the BMS and the wiring all have to handle it.
Taking that 2.4 kWh example, the 48V 60Ah LiFePO4 pack (16S10P) stores about 3.1 kWh and leaves room for margin; the 52V 45Ah Li-ion pack (14S10P) stores about 2.3 kWh and would be too small without opportunity charging during breaks. Charging strategy matters as much as capacity: a robot that tops up at a dock between jobs can carry a much smaller battery than one that has to last a whole shift. Our guide on how to size a battery pack covers the runtime and current calculations step by step.
Long runtime: two and three shifts
A robot that must run for 16 or 24 hours a day has three options: a larger pack, charging during idle time, or swapping packs. Taking the 300 W robot from above over two shifts, 300 W × 16 h = 4.8 kWh, or about 6 kWh with margin. That is our 48V 120Ah LiFePO4 pack (16S20P), 6.1 kWh, but its 320 cells weigh roughly 46 kg before the BMS and enclosure.
Charging during idle time usually wins. If the robot tops up at a dock between tasks, the pack only has to cover the work between two charges, and a pack such as the 48V 60Ah LiFePO4 pack, 3.1 kWh, can keep it running across shifts. LiFePO4 and lithium-ion both accept partial charges, so frequent short top-ups are normal. Our guide to AGV battery charging: opportunity charging or battery swapping works through the numbers, including the charge current the cells and BMS must handle.
A worked example in the Battery Design Studio
Load the 7S10P Molicel P45B configuration in the Battery Design Studio and it shows:
- Nominal voltage: 25.2 V, with a range of 17.5–29.4 V
- Capacity and energy: 45.0 Ah and 1.13 kWh
- Max continuous discharge: 450 A, about 11.3 kW, from the cells
- Cells: 70
- Estimated weight and size: about 5.39 kg and 217 × 152 × 72 mm
These are estimates from typical datasheet values, before the BMS, enclosure and connectors. Open the example and change the series and parallel counts to see how voltage, capacity, size and weight move together.
BMS, communication and protection
Every pack in the range includes a battery management system that protects against over-charge, over-discharge, over-current and short circuit, and balances each series group. For a robot, the BMS is also where several design decisions sit:
- Current rating. In practice, the BMS rating, not the cells, often sets the pack's continuous current. Specify it from the drive's continuous and peak current, and choose it as an option when you order.
- Communication. A smart BMS with CAN bus, RS485, UART, SMBus or Bluetooth lets the robot's controller read the state of charge, voltage, temperature and fault status. Fleet software can then send a robot to charge before it runs low. CAN bus suits robots whose motor controllers and sensors already share a CAN network; RS485 is common on industrial controllers and PLCs; SMBus and UART suit smaller embedded controllers. Tell us the interface, the protocol and the data your controller expects, and we specify the BMS to match.
- Temperature sensing and fusing. Temperature sensors and a fuse can be added to the pack, which matters for machines working in warm warehouses or cold stores.
Read what a BMS does for the full picture.
Connectors, enclosure and mounting
AGVs and robots drive over floor joints, ramps and dock plates every day, so the mechanical side of the pack matters. Our packs can be built with XT60, XT90 or Anderson connectors and the wire length you need, a charge port or charge display, and in flat, tall or custom layouts to fit the chassis. For the outer protection you can choose PVC heat-shrink, a rigid case or a waterproof enclosure. Our guide to battery pack enclosures explains IP ratings and vibration protection.
Safety, testing and shipping
Charge every pack with a matched charger set to the correct voltage for its chemistry and series count, and follow the pack datasheet for storage and handling. Lithium batteries ship under dangerous-goods rules, so the delivery options depend on the destination; if your project needs UN 38.3 or IEC 62133 testing, ask us about certification support. See lithium battery certifications explained and our lithium battery safety guide for more.
Getting a battery for your AGV or robot
Browse the AGV and robot battery range or the LiFePO4 battery packs. Every pack is built to order and priced on request: send us your voltage, peak and continuous current, runtime and space limits, or lay out the pack in the Battery Design Studio and send it from there. Our engineers will recommend a build and confirm the lead time.