Most problems in a battery project are decided in the first hour, when someone writes down a voltage and a capacity and moves on. Here are seven mistakes we see regularly in pack requests, and how to catch each of them early. The examples use figures from our Battery Design Studio, a free 3D tool for laying out a pack, so you can open and change every one of them.
1. Choosing the cell by capacity alone
Two cells of the same size can behave very differently. At 13S4P, a pack of Samsung 50E cells gives 20.0 Ah with a maximum continuous discharge of 39 A. The same 13S4P layout with Molicel P45B cells gives 18.0 Ah and 180 A. If your motor draws 60 A, the higher-capacity pack is the wrong one. Compare them yourself: 13S4P with 50E and 13S4P with P45B.

2. Looking only at the nominal voltage
A pack does not sit at its nominal voltage. A 10S pack is 36.0 V nominal, but it ranges from 25.0 V empty to 42.0 V full. Your motor controller, inverter or electronics must accept the whole range, and your charger must match the top of it. The Studio shows the range next to the nominal voltage for every configuration.
3. Sizing for average current and forgetting the peaks
Start-up, acceleration and pump or compressor loads draw short peaks well above the average. Write down both the continuous current and the peak with its duration. Then check them against the cells, and later against the BMS. How to size a battery pack explains how to get these numbers.
4. Treating the cell limit as the pack limit
The discharge figure in any calculator, ours included, is what the cells can deliver. The finished pack is limited by its weakest link: the BMS, the nickel strip or busbars, the wiring and the connector. A 10S4P pack of Molicel P42A cells shows 180 A at cell level, but nobody should expect that from a pack with a 40 A BMS. This is why the BMS is specified as part of the design, not added at the end. See what a BMS does and how to specify one.
5. Leaving no room for anything but cells
That same 10S4P block of 40 cells measures about 174 × 108 × 72 mm and weighs about 3.08 kg as cells and holders. The housing, padding, BMS, wiring and connectors all add to it. If your drawing leaves exactly the cell volume, the pack will not fit. Check the block size first, then allow for the enclosure: see enclosure materials, IP ratings and vibration. Open the 10S4P example.
6. Picking the chemistry out of habit
Li-ion (NMC/NCA) stores more energy for the same size and weight. LiFePO4 is chosen where long cycle life and thermal stability come first, at a lower energy density. Neither is "better" in general; the application decides. Read LiFePO4 vs lithium-ion before you fix the chemistry.
7. Leaving transport and certification to the end
Lithium batteries are shipped as dangerous goods, and the standards your product must meet depend on its design and destination market. Finding this out after the design is frozen costs time. Raise it in the first conversation: see lithium battery certifications explained.
Catch them in ten minutes
Mistakes 1, 2, 4 and 5 are visible as soon as the pack is on screen. Open the Battery Design Studio, pick a cell, set the series and parallel counts and read the voltage range, current, weight and size. Then send the configuration to us with one click: our engineers check the BMS, current path and enclosure and reply with pricing and lead time. A prototype you can test in your own application comes before any production run; see prototype to production.
The Studio's figures are estimates based on typical cell datasheet values, and final specifications are confirmed by our engineers. Custom battery packs are built for business customers; start at custom battery packs.